Note: Tension meter DX2S do not include a filament guide and material thickness compensator.
Tension Meter DX2S

10 Tension ranges available
from 10 - 50 cN up to 5 - 20 daN
Stationary mechanical tension meter for measuring tensions of fibres, threads, wires, ribbons etc.
Universal tension meter for versatile applications in all sectors of industry
Special purpose models with big, small and tape rollers available
Special Features
Standard Features
– the guide rollers
– the measured material
– the readings
Available Models
Model | Tension Range | Measuring Head Width* | SCHMIDT Calibration Material** |
DX2S-50 | 10 – 50 cN | 54 mm | PA: 0.12 mm Ø |
DX2S-120 | 20 – 120 cN | 54 mm | PA: 0.12 mm Ø |
DX2S-200 | 20 – 200 cN | 54 mm | PA: 0.12 mm Ø |
DX2S-400 | 20 – 400 cN | 54 mm | PA: 0.20 mm Ø |
DX2S-1000 | 50 – 1000 cN | 54 mm | PA: 0.30 mm Ø |
DX2S-2000 | 200 – 2000 cN | 116 mm | PA: 0.50 mm Ø |
DX2S-5000 | 400 – 5000 cN | 116 mm | PA: 0.80 mm Ø |
DX2S-8000 | 1000 – 8000 cN | 116 mm | PA: 1.00 mm Ø |
DX2S-10K | 2.5 – 10 daN | 116 mm | PA: 1.00 mm Ø |
DX2S-20K | 5 – 20 daN | 216 mm | PA: 1.50 mm Ø |
Other units of measure available – g or kg.
* Outer distance between outside guide rollers
** Suitable for 95 % of applications – PA = Polyamide Monofilament
Calibration to customized material:
If process material differs significantly from the SCHMIDT calibration material in diameter, rigidity or shape, special calibration using customer supplied samples is recommended. For this purpose a material sample of about 5 m should be supplied.
Calibration: | According to SCHMIDT factory procedure |
Accuracy: | ±1 % full scale or ±1 graduation on scale |
Scale diameter: | 41 mm |
Temperature range: | 10 – 45 ºC |
Air humidity: | 85 % RH, max. |
Housing material: | Die-cast aluminium |
Dimensions: | See dimensions |
Weight, net (gross): | Up to model DX2S-10K approx. 400 g (800 g) DX2S-20K approx. 500 g (1000 g) |
Specifications subject to change without notice!
SCHMIDT scales are manufactured according to the most stringent quality requirements. Printed scales are not used. Instead, each scale is individually marked for the instrument involved. This ensures highest quality. Our special procedure makes it possible to provide tension meter DX2S
- calibrated to custom supplied material
- fine tuned to a specific tension range
- other units of measure such as g or kg
- DX2S-50
- DX2S-120
- DX2S-200
- DX2S-400
- DX2S-1000
- DX2S-2000
- DX2S-5000
- DX2S-8000
- DX2S-10K
- DX2S-20K
Order-Code | Line Speed vmax. … m/min | Roller Material |
Standard | 2000 | Hard-coated aluminium |
Code K | 3500 | Hard-coated aluminium |
Code H | 5000 | Plasma-coated aluminium (model DX2S-120 and higher) |
Code T | 1000 | Plastic (POM) black |
Code W | 1000 | Nickel-plated steel |
Code ST | 1000 | Hardened steel |
Code B | 1000 | Tempered steel |
Code CE2 | 1000 | Aluminium ceramic-coated |
Code ASY | 1000 | Hard-coated aluminium, asymmetrical groove (model DX2S-120 and higher) |
Code ASYB | 1000 | Tempered steel, asymmetrical groove (model DX2S-120 and higher) |
Code U | 2000 | Hard-coated aluminium (radius R3) |
- Code A - Air Damping
For tension range from 20 – 120 cN up to max. 400 – 5000 cN.
This adjustable mechanical air dashpot is recommended for applications in which great fluctuations of the measured tension occur, as in spooling and winding machines. This assures steady tension readings on scale.
Dimensions of tension meter DX2S for download:
Tension meter DX2S in transport packaging, mounting screws, operating instruction in German or English (as requested), Certificate of Compliance with the order 2.1 according EN 10204 free of charge
To order tension meter DX2S:
Please indicate the complete order number, e. g.:
Model with tension range | Code guide rollers (if nottandard) | Code for attachments | Complete Order-No. | |||
DX2S-400 | + | K | + | A | = | DX2S-400-K-A |