Thickness Gauge D-2005
Measuring range up to 10, 25 or 50 mm
Resolution 0.01 / 0.001 mm
Thickness Gauge to determine the material thickness of all kinds of fabrics. With these instruments the most popular checking methods can be applied for textiles, felt, geomaterials, paper, floor coverings, leather, foils, rubber etc.
Thickness according to international standards DIN, EN ISO or ASTM
Special Features
Standard Features
Power supply of the motor by AC adapter.
Available Models
Model | Standard | Application | Feeler Ø mm | Feeler cm² | Test Pressure |
D-2005-T | DIN EN ISO 5084 | Textiles | 50.42 | 20 | 0.1 kPa and 1 kPa |
D-2005-T1 | ASTM 1777 Version 1 | Textile materials | 28.7 | 6.46 | 4.14 kPa |
D-2005-T2 | ASTM 1777 Version 2 | Textile materials | 9.5 | 0.708 | 23.4 kPa |
D-2005-V | DIN EN ISO 9073-2 | Standard Fleece | 56.42 | 25 | 0.1 and 0.5 kPa |
D-2005-G1 | DIN EN ISO 9863-1 | Geomaterials | 56.42 | 25 | 2 kPa |
D-2005-G2 | DIN EN ISO 9863-1 | Geomaterials | 56.42 | 25 | 2 kPa, 20 kPa and 200 kPa |
D-2005-NW | EN ISO 9073-2 | Non-woven textiles | 56.42 | 25 | 0.5 kPa and 1 kPa |
D-2005-P* | DIN EN ISO 534 | Paper | 16 | 2 | 100 kPa |
D-2005-HY* | DIN EN ISO 54540 | Hygienic paper | 56.42 | 25 | 2 kPa |
D-2005-L | DIN EN ISO 2589 | Leather | 10 | 0.785 | 49,1 kPa |
D-2005-Gi | Rubber | 35.68 | 10 | 5 kPa | |
Feeler Calotte | |||||
D-2005-F* | DIN 53370 | Foil | R 30 mm | 0.5 N |
*Resolution 0.001 mm is standard
We also supply custom designed models, which cover different standards within one instrument. Please inform us, which standards you use and what measuring force and feeler size is required. We will send you our suggestion.
The device is also available as mechanical thickness gauge D-1000 and D-2000 or motorized thickness gauge D-2006, D-2010 and D-2020 with automatic material feed.
Here you can find a comparison table.
Measuring range: | 0 – 10 mm, Option 0 – 25 mm or 0 – 50 mm |
Resolution: | 0.01 mm, Option 0.001 mm |
Accuracy: | ±0.02 mm, Option ±0.002 mm |
Measuring depth: | 110 mm (centre of the stamp) |
Measuring system: | Capacitive -> Sylvac |
Display: | LCD 6 digit, 8.5 mm high |
Measuring unit: | mm or inch (switchable) |
Feeler shape and surface pressure: | According to DIN, EN ISO and ASTM standards |
Output signal: | USB (Sub-D9 socket) |
Power supply dial gauge: | Sub-D9/USB adapter cable |
Power supply motor: | AC adapter 100 – 250 V AC |
Temperature range: | 10 – 45 °C |
Air humidity: | 85 % RH, max. |
Dimensions: | 300 x 240 x 300 mm (LxWxH) |
Weight, net (gross): | Approx. 23 kg (26 kg) |
Specifications subject to change without notice!
Code R | Higher resolution 0.001 instead of 0.01 mm |
Code E25 | Higher measuring range 0 – 25 mm |
Code E50 | Higher measuring range 0 – 50 mm |
DKD-Cal | Calibration report from a DAkkS authorized laboratory |
- Adapter Cable
from Sub-D9 to USB for data transfer to a PC.
The cable also serves the power supply via PC or by using it with the adapter plug at a power source.
Order number: 35008W - AC adapter
AC adapter for power supply of the motor with 100 – 250 V AC.
- Pedal Switch
Pedal switch for moving the motorized feeler.
- Software P-DMG
Software for data transfer, displaying and analysis of measured data on PC
- Adjusting menu:
– Language (German/English)
– Data storage
– Charge No. - Statistical analysis:
– Actual value
– Average value
– Standard deviation
– Maximum
– Minimum
– Register of all readings - Data storage in Excel is possible
Order number: SW-50
- Adjusting menu: