TOP
Menu

Thickness Gauge D-2000

Measuring range up to 10, 25 or 50 mm
Resolution 0.01 / 0.001 mm

Thickness Gauge to determine the material thickness of all kinds of fabrics. With these instruments the most popular checking methods can be applied for textiles, felt, geomaterials, paper, floor coverings, leather, foils, rubber etc.

Thickness according to international standards DIN, EN ISO or ASTM

CE mark

Special Features


Thickness gauge D-2000 is working according international DIN, EN, ISO and ASTM standards. They measure with highest accuracy.

The instruments are mainly designed for laboratory use

Different measuring feelers and additional weights are available depending on the application area and test standard; on request different standards can be combined in one instrument

The standard measuring range is 0 – 10 mm; 25 and 50 mm are optional available

The resolution is 0.01 mm; as option 0.001 is available

Thickness gauge D-2000 with USB interface (Sub-D9 socket) and Sub-D9/USB adapter cable for data transfer

The feeler is move up and down by using a mechanical plunger

Robust, bend-resistant device construction, encapsulated against external influences, e.g. shock; this ensures maximum measurement and repeatability

Standard Features


Thickness gauge D-2000 with LCD display – switchable measuring units mm / inch

Gauge with external power supply via the USB interface

The instrument is easy to use

Calibration report for free, DAkkS inspection certificate optional

Available Models

ModelStandardApplicationFeeler
Ø mm
Feeler
cm²
Test Pressure
D-2000-TDIN EN ISO 5084Textiles50.42200.1 kPa and 1 kPa
D-2000-T1ASTM 1777 Version 1Textile materials28.76.464.14 kPa
D-2000-T2ASTM 1777 Version 2Textile materials9.50.70823.4 kPa
D-2000-VDIN EN ISO 9073-2Standard Fleece56.42250.1 and 0.5 kPa
D-2000-G1DIN EN ISO 9863-1Geomaterials56.42252 kPa
D-2000-G2DIN EN ISO 9863-1Geomaterials56.42252 kPa, 20 kPa and 200 kPa
D-2000-NWEN ISO 9073-2Non-woven textiles56.42250.5 kPa and 1 kPa
D-2000-P*DIN EN ISO 534Paper162100 kPa
D-2000-HY*DIN EN ISO 54540Hygienic paper56.42252 kPa
D-2000-LDIN EN ISO 2589Leather100.78549,1 kPa
D-2000-GiRubber35.68105 kPa
Feeler
Calotte
D-2000-F*DIN 53370FoilR 30 mm0.5 N

*Resolution 0.001 mm is standard

We also supply custom designed models, which cover different standards within one instrument. Please inform us, which standards you use and what measuring force and feeler size is required. We will send you our suggestion.
The device is also available as mechanical thickness gauge D-1000 and motorized thickness gauge D-2005, D-2006, D-2010 and D-2020 with automatic material feed.
Here you can find a comparison table.

Specifications

Measuring range:0 – 10 mm, Option: 0 – 25 mm (Code E25) or 0 – 50 mm (Code E50)
Resolution:0.01 mm, Option: 0.001 mm (Code R)
Accuracy:±0.02 mm, Option: ±0.002 mm (Code R)
Measuring depth:110 mm (centre of the stamp)
Measuring system:Capacitive -> Sylvac
Display:LCD 6 digit, 8.5 mm high
Measuring unit:mm or inch (switchable)
Feeler shape and surface pressure:According to DIN, EN, ISO and ASTM standards
Output signal:USB (Sub-D9 socket)
Temperature range:10 – 45 °C
Air humidity:85 % RH, max.
Dimensions:300 x 240 x 300 mm (LxWxH)
Weight, net (gross):Approx. 23 kg (26 kg)

Specifications subject to change without notice!

Attachment (optional)

Code RHigher resolution 0.001 instead of 0.01 mm and higher accuracy 0.002 instead of 0.02
Code E25 Higher measuring range 0 – 25 mm
Code E50Higher measuring range 0 – 50 mm
DKD-Cal Calibration report from a DAkkS authorized laboratory

Standard Accessories

  1. Adapter cable

    Adapterkabel für Dickenmesser D-2000from Sub-D9 to USB for data transfer to a PC.
    The cable also serves the power supply via PC or by using it with the adapter plug at a power source.
    Order number: 35008W


Software (optional)

  1. Software P-DMG

    Software P-DMG für DickenmesserSoftware for data transfer, displaying and analysis of measured data on PC

    • Adjusting menu:
      – Language (German/English)
      – Data storage
      – Charge No.
    • Statistical analysis:
      – Actual value
      – Average value
      – Standard deviation
      – Maximum
      – Minimum
      – Register of all readings
    • Data storage in Excel is possible
      Order number: SW-50

Delivery Includes

Thickness Gauge D-2000 with transport packing case, Sub-D9/USB adapter cable, USB AC adapter, calibration report of manufacturer and operating instructions in English or German

Instruction Manual

Download the instruction manual for thickness gauge D-2000:

If you want to get a quote or want to place an order, please contact us!


+49 (0)8638 9410-0

+49 (0)8638 4825