– analog: 0 – 1 V DC (standard), 0 – 10 V DC (optional)
– current: 4 – 20 mA (optional)
– analog DMS: mV/V (optional)
Stationary electronic tension sensor for continuous measuring low and high tensions of textile ribbons, films, foils, fibre bunches etc.
Tape rollers, supported on both sides, with width from 15 mm up to 100 mm
Tension sensor for quick and easy mounting
Note:
Various customized designs and modifications are possible. Please contact us.
Please submit the following details:
– description of application
– expected tension range
– kind and dimensions of the material to be measured
– available place for installation
– material sample of about 5 m
Model | Tension Range* | Roller Width |
TSB2-500 | 0 – 500 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-1000 | 0 – 1000 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-2000 | 0 – 2000 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-5000 | 0 – 5000 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-10K | 0 – 10 daN | 15, 20, 30, 36, 41, 50, 100 mm |
TSB2-20K | 0 – 20 daN | 15, 20, 30, 36, 41, 50, 100 mm |
TSB2-50K | 0 – 50 daN | 15, 20, 30, 36, 41, 50, 100 mm |
TSB2-100K | 0 – 100 daN | 15, 20, 30, 36, 41, 50, 100 mm |
Important for your order:
Please specify model and roller width! All 3 rollers are small dual-flanged.
Calibration to customized material:
If process material differs significantly from the SCHMIDT calibration material in dimension, rigidity or shape, special calibration using customer supplied samples is recommended. For this purpose a material sample of about 5 m should be supplied.
For the tension sensor TSB2 we offer different display units for one or more sensors, as well as strain gauge amplifier.
Find further information at display units and amplifier
Tension Sensor TSB2 can be reconverted for special applications.
Find further information at special design
Calibration: | According to SCHMIDT factory procedure |
Accuracy: | ±1 % full scale and ±1 digit Other calibration material: ±3 % full scale or better |
Overload protection: | 100 % of tension range |
Measuring principle: | Strain gauge bridge |
Measuring roller deflection: | Max. 0.5 mm |
Natural frequency: | Approx. 500 Hz, depending on tension range |
Signal processing: | Analog |
Temperatur drift: | Less than ±0.05 % full scale/ºC |
Output signal: | Standard: 0 – 1 V DC (analog) impedance: ≥ 5 kΩ Option: 0 – 10 V DC (analog), 4-20 mA (current) or mV/V (DMS) |
Damping (fg): | Standard: 30 Hz (other values on request) |
Temperature range: | 10 – 45 ºC |
Air humidity: | 85 % RH, max. |
Power supply: | +15…24 V DC, 21 mA regulated Code A3: max. 50 mA regulated Code A10: max. +5 V DC, max. 20 mA regulated |
Housing material: | Aluminium |
Weight, net (gross): | E. g. model TSB2-2000-50 approx. 1000g (1400 g) |
Specifications subject to change without notice!
Roller Width | Line Speed vmax. … m/min | Roller Material |
15 mm | 1000 | Aluminium hardcoated |
20 mm | 1000 | Aluminium hardcoated |
30 mm | 1000 | Aluminium hardcoated |
36 mm | 1000 | Aluminium hardcoated |
41 mm | 1000 | Aluminium hardcoated |
50 mm | 1000 | Aluminium hardcoated |
100 mm | 1000 | Aluminium hardcoated |
*Other roller materials (nickel-plated steel or plastic), as well as special coatings (Code CF – for carbon fibre, NA optimized, Code KE – ceramic,
Code AH – anti adhesive) are available on request.
Diode plug suitable for sensors of TS series,
cable outlet 3.5 – 6 mm
Order number: E10061
Connecting cable with 2 diode plugs, for analog output and voltage signal.
For connecting the TS sensor to the display unit SCD-1.
Order number: EK0603, Länge 3 m
Order number: EK0605, Länge 5 m
Order number: EK0610, Länge 10 m
Connecting cable with 1 diode plug and open ends, for analog output and current signal.
For connecting sensors of TS series to the display unit SC-PM.
Order number: EK0612, Länge 3 m
Order number: EK0614, Länge 5 m
Order number: EK0615, Länge 10 m
Other cable length available on request!
Please indicate the complete order number e.g.:
Model with tension range | Roller width in mm | Code output signal (if not standard) | Complete Order No. | |||
TSB2-10K | + | 20 | + | A2 | = | TSB2-10K-20-A2 |