– Readings with alarm control
– Bar chart, reading and alarm control
– digital (standard): USB (front side), RS-422 (rear side)
– analog (optional): 0 – 10 V DC (rear side)
Panel mount digital display for max. 4 tension sensors. Outputs: USB, RS-422 and analog .
4 different calibrations for customer supplied material can be saved for each channel
Using the USB or RS-422 output all tension readings can be sent to PC for data analysing and storage
Model | Connectable Sensors | Output Signal |
SC-PM4 | Sensors with amplifier (0 – 1 V) | USB, RS-422, open collector |
SC-PMD4 | Sensors without amplifier (mV/V) | USB, RS-422, open collector |
Digital display: | Graphic LCD display with backlight |
Engineering units: | cN, daN, g, kg, lb or oz selectable |
Adjustment: | 4 material curves for each channel can be stored |
Selectable Damping: | 9 adjustable settings |
Signal processing: | Digital |
Output signal: | Digital (standard): USB and RS-422 (57600, 8, N, 1) Analog (option): 0 – 10 V DC /RLast ≥ 5kΩ |
Input signal: | 0 – 1 V DC, option mV/V |
Alarm limits: | Programmable MIN.- MAX limits per sensor |
Output signal of the alarm limits: | Open collector per Sensor (common signal for MIN. and MAX.), max. 30 V DC, 10 mA |
Exit hub: | Terminal strip |
Power supply for sensor: | Yes |
Power supply: | 15 – 24 V DC, 100 mA |
Temperature range: | 10 – 45° C |
Air humidity: | 85 % RH, max. |
Housing: | Plastics |
Dimensions: | 110 x 90 x 90 mm (LxWxH), mounting cut out 91.5 x 91.5 mm |
Weight, net (gross): | Approx. 300 g (700 g) |
Specifications subject to change without notice!
Cable for the USB output to connect the tension meter to a PC.
Cable length 1,50 m
Order number: EK0662
Software for displaying and saving readings on a PC (Win 7 and higher; 32 bit and 64 bit).
Only for display units with digital output signal.
Features:
– Real-time reading
– The readings are also shown in a X-Y- diagram (time/date-tension)
– For data analysing the buffered diagram can be zoomed and scaled
– Recording of the buffered readings as CSV-file (on user request)
– Download of values to Excel
Max. 4 Sensors can be monitored
Order number: SW-TI3-4
Cable with 1 Diode plug and open ends for analog output and current signal.
For connecting sensors of TS series to the display unit SC-PM.
Order number: EK0612, Length 3 m
Order number: EK0614, Length 5 m
Order number: EK0615, Length 10 m
Cable with 1 SUB M9 sub-minimatur plug and open ends cable for the analog output.
For connecting sensors of FS series to the display unit SC-PM.
Order number: EK0620, Length 2 m
Order number: EK0621, Length 5 m
Order number: EK0627, Length 10 m
Cable with 1 SUB M9 sub-minimatur right angle plug and open ends cable for the analog output.
For connecting sensors of FS series to the display unit SC-PM.
Order number: EK0622, Length 2 m
Order number: EK0623, Length 5 m
Converter from RS-422 to RS-232 with terminal strip
Order number: EBG800
Cable to extend the RS-232 connecting cable EK0640 or for connecting the converter with a PC, length 2 m
Order number: EK0643
Recharger with 4 adapters (EU/USA/UK/AUS-NZL) for worldwide use,
100 – 240 V AC
Order number: K50204
Standard
Output signal:
digital: USB
4 x open collector
To connect the display to a PC.
Max. 200 readings can be transferred per second.